This is a demo store. No orders will be fulfilled.

6000 Series Geroler Motors, Up To 16580 lb-in Intermittent Torque, 866 Intermittent RPM

Fluid Viscosity Minimum: 70 SUS at operating temperature. Recommended Range: 100-200 SUS.
Maximum Case Pressure 1000 PSI (Without case drain). For continuous back pressure over 1000 PSI, use an external case drain line. Install line so motor case remains full at all times.
Maximum Operating Temperature 180° F.
Recommended Break-In To assure best motor life, run motor for approximately one hour at 30% of rated pressure before application to full load. Be sure motor is filled with fluid prior to any load applications.
Recommended Filtration Per ISO Cleanliness Code, level 18/13.
Recommended Fluids Premium quality, anti-wear type hydraulic fluid.

Products