Ear Pinch Clamp Installation Tools

1-Ear Clamp Installation 1-Ear clamps are best installed when the clamp shows a gap of approximately 1/16 inch. This builds a resilient strength into the clamp in a spring-like action to hold against pressure, vibration and hose shrinkage due to temperature changes or aging. (If a clamp ear can be closed all the way, the clamp size selected is probably too big and the next smaller clamp should be used).
2-Ear Clamp Installation While both ears must be closed, 2-Ear clamps are best installed when one ear is closed all the way first. The second ear is then closed so that the first ear opens slightly (gap to be approximately 1/16 inch). This builds a resilient strength into the clamp in a spring-like action to hold against pressure, vibration and hose shrinkage due to temperature changes or aging. (If both ears can be closed all the way, the clamp size selected is probably too big and the next smaller clamp should be used).